Technology |
LASER scanner, Time-of-Flight measurement |
---|---|
Detection Mode |
Presence |
Max. Detection Range |
13’ (diagonal) with reflectivity of 2% |
Recommended Mounting Height |
|
Opening Angle |
Door leaf safety: 80° |
Angular Resolution |
Curtain 1: 0.2° |
Tilt Angles |
0 – 5° |
Typ. Min. Object Size |
¾” @ 13’ in curtain C1 |
Emission Characteristics |
IR LASER: wavelength 905 nm; output power < 0.1mW; |
Supply Voltage* |
12 – 24 VDC ±15% (to be operated from SELV-compatible power supplies only) |
Power Consumption |
< 2 W |
Response Time |
Typ. < 120 ms (Max. 220 ms) |
Output |
3 electronic relays (galvanic isolation - polarity free) |
Dimensions |
5 ¾” (L) × 3 ½” (H) × 2 ⅓” (D) |
Material - Color |
PC / ASA - Black |
Protection degree |
IP44 (IEC 60529) |
LED Signals |
1 RGB LED: detection/output status |
Temperature Range |
-13 – 140 °F |
Humidity |
0 – 95% non-condensing |
Vibrations |
< 2 G |
Compliance |
ISO 13849-1 Pl “d”/ CAT2; IEC 60825-1; IEC 62061 SIL 2 |
* This sensor is powered by DC voltage only. If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product.