airporthospitalsindustrylogisticsretailfoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofoofooAsset 3foofoofoofoofoofooArtboardfacebookinstagramlinkedintwitteryoutubeempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

UL Listed Maglocks

Maglocks with adjustable relock time delay, lock status sensor and optional door status sensor
ul-listed-maglocks

Description

BEA’s UL Listed Maglock portfolio provide a standards compliant locking solution for retail, healthcare, banking and other high security facilities that require UL Listed security products. Maglocks can be used on hollow metal, wood, aluminum, glass and composite door materials.

The UL Listed Maglocks are available in surface mount single or double door configurations, with holding force of 600 or 1,200 lbs. These locks include adjustable 0-90 sec relock time delay and a lock status sensor with visible LED.

The Maglock with DS is available in surface mount, single or double door configurations, with a holding force of 600 or 1,200 lbs. These locks include an adjustable 0-90 sec relock time delay, lock status sensor with visible LED and door status sensor.

Features

Customizable

Adjustable 0-90 second relock time delay

LED for enhanced reliability

Lock Status Sensor with visible LED

UL Listed

Input voltage of 12/24 VDC, must be used with UL Listed power supply

Additional features

DS models include a door status sensor

Table of specifications

10MAGLOCK3ULDS

   

Door Configuration

Single, surface mount

 

Holding Force

600 lb

 

Input Voltage

12 or 24 VDC (UL Listed power supply required)

 

Current Draw

0.50 A @ 12 VDC
0.25 A @ 24 VDC

 

Dimensions

9.84 in (W) × 1.65 in (H) × 1.02 in (D)

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor, Door Status Sensor

 

Output Relay

Up to 1 A @ 24 VDC

 

 

   

10MAGLOCK6ULDS

   

Door Configuration

Double, surface mount

 

Holding Force

600 lb

 

Input Voltage

12 or 24 VDC (UL Listed power supply required)

 

Current Draw

1 A @ 12 VDC
0.50 A @ 24 VDC

 

Dimensions

19.76 in (W) × 1.65 in (H) × 1.02 in (D)

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor, Door Status Sensor

 

Output Relay

Up to 1A @ 24 VDC

 

 

   

10MAGLOCK1ULDS

   

Door Configuration

Single, surface mount

 

Holding Force

1200 lb

 

Input Voltage

12 or 24 VDC (UL Listed power supply required)

 

Current Draw

0.50 A @ 12 VDC
0.30 A @ 24 VDC

 

Dimensions

10.47 in (W) × 2.87 in (H) × 1.58 in (D)

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor, Door Status Sensor

 

Output Relay

Up to 1 A @ 24 VDC

 

 

   

10MAGLOCK5ULDS

   

Door Configuration

Double, surface mount

 

Holding Force

1200 lb

 

Input Voltage

12 or 24 VDC (UL Listed power supply required)

 

Current Draw

1 A @ 12 VDC
0.60 mA @ 24 VDC

 

Dimensions

20.94 in (W) × 2.87 in (H) × 1.58 in (D)

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor, Door Status Sensor

 

Output Relay

Up to 1 A @ 24 VDC

 

 

   

10MAGLOCK3UL

   

Door Configuration

Single, surface mount

 

Holding Force

600 lb

 

Input Voltage

12 or 24 VDC (UL listed power supply required)

 

Current Draw

0.50 A @ 12 VDC
0.25 A @ 24 VDC

 

Dimensions

9.84 in (W) × 1.65 in (H) × 1.02 in (D)

 

Material

Anodized Aluminum housing

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor (NO or NC outputs

 

Output Relay

Up to 1 A @ 24 VDC

 

 

   

10MAGLOCK6UL

   

Door Configuration

Double, surface mount

 

Holding Force

600 lb

 

Input Voltage

12 or 24 VDC (UL Listed power supply required)

 

Current Draw

1 A @ 12 VDC
0.50 A @ 24 VDC

 

Dimensions

19.76 in (W) × 1.65 in (H) × 1.02 in (D)

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor (NO or NC outputs)

 

Output Relay

Up to 1 A @ 24 VDC

 

 

   

10MAGLOCK1UL

   

Door Configuration

Single, surface mount

 

Holding Force

1200 lb

 

Input Voltage

12 or 24 VDC (UL listed power supply required)

 

Current Draw

0.50 A @ 12 VDC
0.30 A @ 24 VDC

 

Dimensions

10.47 in (W) × 2.87 in (H) × 1.58 in (D)

 

Material

Anodized Aluminum housing

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor (NO or NC outputs)

 

Output Relay

Up to 1 A @ 24 VDC

 

 

   

10MAGLOCK5UL

   

Door Configuration

Double, surface mount

 

Holding Force

1200 lb

 

Input Voltage

12 or 24 VDC (UL listed power supply required)

 

Current Draw

1 A @ 12 VDC
0.60 A @ 24 VDC

 

Dimensions

20.94 (W) in × 2.87 in (H) × 1.58 in (D)

 

Material

Anodized Aluminum housing

 

Relock Time Delay

0 s – 90 s

 

Sensor

Lock Status Sensor (NO or NC outputs)

 

Output Relay

Up to 1 A @ 24 VDC

 
Versions
  • 10MAGLOCK3ULDS

    600 lb single, surface mount with door status sensor

  • 10MAGLOCK6ULDS

    600 lb double, surface mount with door status sensor

  • 10MAGLOCK1ULDS

    1200 lb single, surface mount with door status sensor

  • 10MAGLOCK5ULDS

    1200 lb double, surface mount with door status sensor

  • maglock1ul_3ul
    10MAGLOCK3UL

    600 lb single, surface mount

  • maglock5ul_6ul
    10MAGLOCK6UL

    600 lb double, surface mount

  • maglock1ul_3ul
    10MAGLOCK1UL

    1200 lb single, surface mount

  • maglock5ul_6ul
    10MAGLOCK5UL

    1200 lb double, surface mount

Accessories
  • l-z-brackets
    L & Z Brackets

    L & Z Brackets for 600lb and 1200 lb single and double BEA Maglocks.

  • u-bracket
    U Brackets

    Glass door mounting kit for BEA Maglocks.

  • filler-plate
    Filler Plates

    Maglock filler plate

  • armature-plates
    Armature Plate Housings

    BEA’s Armature Plate Housings provide a more aesthetically pleasing look over that of standard armature plates.

  • spacer-brackets
    Spacer Brackets

    BEA Maglock Spacer Brackets are used when the stop requires the Maglock to be lowered.

Downloads
Frequently asked questions

Can I use a transformer and a rectifier to power a MAGLOCK?

No. UL MAGLOCKS must be powered from a UL-listed, regulated, power-limited, power supply.

 

I have an all-glass, swing door. How do I mount the armature plate?

Use the U-Bracket (10UBRACKETUL) to mount the armature to the swing door.

 

How do I mount a MAGLOCK to be used on the pull side of a swing door?

Use the L and Z bracket kit:
   600lb single = 10LZBRMAG3UL
   1200lb single = 10LZBRMAG1UL
   600lb double = 10MAG6LZUL
   1200lb double = 10MAG5LZUL

 

Why is the lock not releasing after I connect my Push-to-Exit switch to the COM. and N.O. terminals on the terminal strip?

That is a Lock Status relay that switches state when the bond occurs; not a lock release.

 

Why will the MAGLOCK not bond to the armature even though the red LED is on?

Verify that your power supply has sufficient amperage. Verify that you have the correct power supply; it must be a UL-listed, regulated, power-limited, power supply.

 

Why is the bond between the MAGLOCK and the armature plate weak?

Verify the amperage. If the power is good, remove the spring-loaded button attached to armature plate.
Verify that the armature plate is properly aligned with the MAGLOCK body.

 

Can I replace only the board of the MAGLOCK body?

No. The entire MAGLOCK assembly must be replaced.

 

What is the default voltage for the jumpers?

24 VDC

 

Why won’t the LED turn Green?

1. The armature plate is too tight on door.
2. The armature plate is out of alignment.
3. The wrong power supply is being used.

 

What does the potentiometer do?

For setting a re-locking delay (up to 90 seconds) when using a momentary switch to release the lock.

 

See all our products