POWER SUPPLY ENCLOSURE |
|
---|---|
Agency listings |
UL294, cUL, CSFM, MEA, NFPA 101 |
Input |
115VAC, 60Hz, 0.6A. |
Output |
12VDC or 24VDC |
Supervision |
AC fail supervision |
Fire alarm interface |
Dry trigger input |
Visual indicators |
AC input and DC output LED indicators |
Enclosure dimensions |
13.5” × 13” × 3.25” |
|
|
LOGIC MODULE |
|
Supply voltage |
12 − 24 VAC/VDC ±10% |
Current consumption |
30 − 130 mA (DRY output) |
Temperature rating |
-15 − 150 °F (-26 − 150 °C) |
Input |
|
Contact rating |
|
Dimensions |
5.2” x 2.2” x 1” (133 mm x 55 mm x 25 mm) |
Housing |
ABS - white translucent |
|
|
MS42 |
|
Technology |
microwave motion sensor |
Radiated frequency |
24.150 GHz |
Detection range |
4 – 24” (adjustable) |
Supply voltage* |
12 – 24 VAC ±10% |
Power consumption |
< 1.5W |
Output* |
Electronic relay (galvanic isolation - polarity free) |
Temperature range |
-20 – 55 °C |
IP rating |
IP55 |
Certification |
EMC: 2004/108/EC |
|
|
DOOR POSITION SWITCH |
|
Gap distance |
0.43” |
Loop |
open |
Reed form |
N.C. |
Max. contact rating |
3 W |
Max. initial contact resistance |
100 mΩ |
Max. switching voltage |
30 VAC/VDC |
Max. switching current |
0.2 A |
Color |
white |
Leads length |
12”, 22 AWG |
Contact size |
1.1” (L) × 0.37” (W) × 0.19” (H) |
* External electrical sources must be within specified voltages (max 15 W) and ensure double insulation from primary voltages.