i-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitairporthospitalsindustrylogisticsretailArtboardempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Frequently Asked Questions

Why won’t the BR3-X operate after I select a function?

The relay hold times are set to 0. Set them to a value greater than 0.

Why does the BR3-X display “E2”?

This is caused by a power (voltage/amperage) event. Cycle power and reprogram.

With the BR3-X set to function 28 or 36 why is the door attempting to open but the strike is not releasing?

The jumpers or voltage may be incorrect. Move the jumpers to WET and meter the output voltage/continuity.

How do I program the BR3-X to lock out a BODYGUARD?

The BR3-X cannot be programmed to lock out a BODYGUARD. You must use an LO21 series lockout module.

What is the “r” with small horizontal lines?

Each of the three (3) small horizontal lines represents 1 of the 3 relays; the top line represents relay 1, the middle line represents relay 2, and the bottom line represents relay 3. Multiple lines indicate which relays are energized simultaneously.

With the BR3-X set to function 36 why will the door not open?

The relay hold times are set to 0. Set them to a value greater than 0.

How do I program a function when the BR3-X flashes “NP”?

Wait until “NP” stops blinking (~ 5 seconds) and the display shows “00”, and then reprogram.

How do I achieve BR3 function 25 functionality with the BR3-X?

Functions 28, 36, or 37 on the BR3-X can both be used in the same manner as function 25 on the BR3.

Does the BR3-X have the same functions as the BR3?

Yes, all BR3 functionality (and more) can be achieved using the BR3-X. See the User’s Guide for a function cross-reference.

Do I have to change both jumpers for wet output functionality?

Yes, in order to get voltage (wet output) out of relay 1, you will need to set both jumpers to WET; additionally, the common is the positive (+) terminal and the N/O or N/C is the negative (-) terminal.