The relay hold times are set to 0. Set them to a value greater than 0.
This is caused by a power (voltage/amperage) event. Cycle power and reprogram.
The jumpers or voltage may be incorrect. Move the jumpers to WET and meter the output voltage/continuity.
The BR3-X cannot be programmed to lock out a BODYGUARD. You must use an LO21 series lockout module.
Each of the three (3) small horizontal lines represents 1 of the 3 relays; the top line represents relay 1, the middle line represents relay 2, and the bottom line represents relay 3. Multiple lines indicate which relays are energized simultaneously.
The relay hold times are set to 0. Set them to a value greater than 0.
Wait until “NP” stops blinking (~ 5 seconds) and the display shows “00”, and then reprogram.
Functions 28, 36, or 37 on the BR3-X can both be used in the same manner as function 25 on the BR3.
Yes, all BR3 functionality (and more) can be achieved using the BR3-X. See the User’s Guide for a function cross-reference.
Yes, in order to get voltage (wet output) out of relay 1, you will need to set both jumpers to WET; additionally, the common is the positive (+) terminal and the N/O or N/C is the negative (-) terminal.