10STRIKERE |
|||
---|---|---|---|
Mode |
Fail Safe |
||
Voltage |
12 VAC / VDC |
24 VAC / VDC |
11 - 16 VAC |
Duty |
Intermittent, Continuous |
Intermittent, Continuous |
Intermittent, Intermittent |
Amps † |
0.30, 0.50 |
0.64, 0.24 |
0.35, 0.50 |
Sound |
Buzz, Silent |
Buzz, Silent |
Buzz, Buzz |
Static / Dynamic Strength |
1500 lbs / 70 lbs |
||
Endurance |
250,000 cycles (UL tested) |
||
Latch Throw |
¾” |
||
Standards Compliance |
UL 294, UL 1034, UL & cUL listed |
||
|
|||
10STRIKECU |
|||
Mode |
Fail Safe |
Fail Secure |
|
Voltage |
12 VDC |
24 VDC |
12 – 24 VAC |
Duty |
Continuous |
Continuous |
Intermittent |
Amps † |
0.375 |
0.190 |
0.280 – 0.565 |
Sound |
Silent |
Silent |
Buzz |
Amps † |
0.375 |
0.190 |
0.280 – 0.565 |
Static / Dynamic Strength |
1000 lbs / 70 lbs |
||
Endurance |
250,000 cycles (UL tested) |
||
Latch Throw |
½” or ⅝” |
||
Standards Compliance |
UL 294, UL 1034, UL & cUL listed |
||
|
|||
10STRIKEREV12 / 10STRIKEREV34 |
|||
Mode |
Fail Safe |
Fail Secure |
|
Voltage |
12 VDC |
24 VDC |
|
Duty |
Continuous |
Continuous |
|
Amps † |
0.540 |
0.270 |
|
Sound |
Silent |
Silent |
|
Static / Dynamic Strength |
1500 lbs / 70 lbs |
||
Endurance |
250,000 cycles (UL tested) / 1,000,000 cycles (factory tested) |
||
Latch Throw |
½” or ¾” |
||
Standards Compliance |
UL 294, UL 1034, UL listed |
||
|
|||
10STRIKECUV |
|||
Mode |
Fail Safe |
Fail Secure |
|
Voltage |
12 VDC |
24 VDC |
|
Duty |
Continuous |
Continuous |
|
Amps † |
0.300 |
0.150 |
|
Sound |
Silent |
Silent |
|
Static / Dynamic Strength |
1000 lbs / 70 lbs |
||
Endurance |
250,000 cycles (UL tested) / 1,000,000 cycles (factory tested) |
||
Latch Throw |
9⁄16; (15 mm max) |
||
Standards Compliance |
UL 294, UL 1034, UL listed |
Fail Safe – Lock or locking device that remains unlocked on loss of power
Fail Secure – Lock or locking device that remains locked on loss of power.
Also known as Non-Fail Safe (NFS)
Intermittent Duty – Energized less than 1 minute with duty ratio 1:5
Continuous Duty – Energized 1 minute or more
† Amp ratings are based on maximum current draw at 50 ºF and include initial power-up current
‡ Nominal resistance at 77 ºF ±7% tolerance