Technology |
Active Infrared |
---|---|
Detection Mode |
Presence |
Mains Frequency |
50 – 60 Hz |
Power Consumption |
< 3.5 W |
Relay Output |
2 Relays (free of potential change-over contact) |
Supply Voltage |
12 – 24 VAC ±10% |
Temperature Range |
-22 – 140 °F |
Tilt Angle |
15 – 45º |
Transmitter Frequency / Wavelength |
875 nm |
Transmitter Power Density |
< 250 mW/m2 |
Detection Field |
10’ × 10’ @ max. mounting height of 16’ |
Output Hold Time |
0.5 s |
Min. Detection Speed |
0 in / s to activate detection |
Reaction Time |
250 ms |
Mounting Height |
8 – 16’ |
Humidity |
0 – 95% non-condensing |
Weight |
14 oz |
Dimensions |
3 4⁄5“ (W) × 4” (H) × 5” (D) |
Material |
ABS & Polycarbonate |
Cable Length |
32’ |
Degree of Protection |
IP65 |
Norm Conformance |
EMC: 2004/108/EEC |
*Zone detected by Spotfinder, i.e. slightly larger than actual detection field