Technology |
LASER scanner, time-of-flight measurement |
---|---|
Measurement range |
max. 26’3” (8 m) |
Number of planes |
1 |
Number of points/plane* |
max. 400 pts |
Angular resolution* |
min. 0.18° |
Angular coverage* |
max. 108° |
Response time |
measurements are refreshed every: |
Scanning rate |
93 scans/sec. @ angular resolution ≥ 0.74° |
Emission characteristics |
IR LASER: Wavelength 905 nm; max. output pulse power |
Measurement error |
± 1 3⁄16” @ 13’ (±30mm @ 4m) |
Repeatability |
± 3⁄16” @ 13’ (±5mm @ 4m) |
Serial communication |
see LZR®-FLATSCAN U Protocol (available for download on |
Supply voltage |
12 – 24 VDC ±15% |
Power consumption |
< 2 W |
Peak current at power-on |
0.8 A (max. 20 ms @ 24 V) |
Cable length |
8 ¼’ (2.5m) |
Connector |
DF11-6DS-2C |
Dimensions (U950 only) |
5 ½” (L) × 3 ⅓” (H) × 1” (D) |
Material - Color (U950 only) |
PC/ASA - Black |
Tilt angles (U950 only) |
-2 – 6° (with mounting base) |
Protection degree (U950 only) |
IP54 [IEC 60529] |
Temperature range |
powered: -22 – 140 °F (-30 – 60 °C) |
Humidity |
0 – 95% non-condensing |
Vibrations |
< 2 G |
Compliance |
2014/30/EU; 2011/65/EU; IEC/EN 60825-1 Laser safety; IEC/EN |
* These parameters can be configured via the RS 485 communication interface. For more information