ArtboardairporthospitalsindustrylogisticsretailfacebookinstagramlinkedintwitterwechatYouku-iconyoutubei-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Technology

LASER scanner, time-of-flight measurement

Measurement range

max. 26’3” (8 m)
13’ (4m) @ 2% remission factor
26’3” (8 m) @ 8% remission factor

Number of planes

1

Number of points/plane*

max. 400 pts

Angular resolution*

min. 0.18°

Angular coverage*

max. 108°

Response time

measurements are refreshed every:
10.75 ms @ angular resolution ≥ 0.74°
43 ms @ angular resolution < 0.74°

Scanning rate

93 scans/sec. @ angular resolution ≥ 0.74°
23.25 scans/sec. @ angular resolution < 0.74°

Emission characteristics

IR LASER: Wavelength 905 nm; max. output pulse power
25 W; Class 1

Measurement error

± 1 3⁄16” @ 13’ (±30mm @ 4m)
± 2 ¾” @ 26 1/4’ (±70mm @ 8m)

Repeatability

± 3⁄16” @ 13’ (±5mm @ 4m)
± 25⁄64 @ 26 1/4’ (±10mm @ 8m)

Serial communication
 
Type
Interface
Communication mode
Transmission speed
Topology
Symbol coding
Type
File type
Byte order

see LZR®-FLATSCAN U Protocol (available for download on
our website)
asynchronous
RS 485
full-duplex
max. 921,600 bit/sec (configurable)
point to point
1 start bit, 1 stop bit, no parity bit
8 bits
little endian, LSB first
1 tri-colored LED: sensor/communication status

Supply voltage

12 – 24 VDC ±15%

Power consumption

< 2 W

Peak current at power-on

0.8 A (max. 20 ms @ 24 V)

Cable length

8 ¼’ (2.5m)

Connector

DF11-6DS-2C

Dimensions (U950 only)

5 ½” (L) × 3 ⅓” (H) × 1” (D)
[142mm (L) × 85mm (H) × 23mm (D)]
mounting bracket + ¼” (7mm)

Material - Color (U950 only)

PC/ASA - Black

Tilt angles (U950 only)

-2 – 6° (with mounting base)
2 – 10° (without mounting base)

Protection degree (U950 only)

IP54 [IEC 60529]

Temperature range

powered: -22 – 140 °F (-30 – 60 °C)
unpowered: 14 – 140 °F (-10 – 60 °C)

Humidity

0 – 95% non-condensing

Vibrations

< 2 G

Compliance

2014/30/EU; 2011/65/EU; IEC/EN 60825-1 Laser safety; IEC/EN
61000-6-2; IEC/EN 61000-6-3 EMC

* These parameters can be configured via the RS 485 communication interface. For more information
on the existing options, see LZR-FLATSCAN U Protocol.

See all our products

Subscribe to our newsletter

Learn more