No configuration necessary. The DE MAGLOCK is auto-sensing.
No. DE MAGLOCKS must be powered by a filtered and regulated, UL-listed power supply.
Check with your local AHJ for the local codes, and then set accordingly.
Typically, the armature plate mounting bolt is too tight. Try loosening a quarter-turn at a time, until you get a bond.
Turn off DIP 1 on DIP bank 2, and then install an appropriate REX switch in an exit device with the white and blue wires terminated to the exit device.
Yes. It will require a dry output from your access control that signals the brown and brown/white wires when a reset is required.
NOTE: Local codes may dictate/mandate/require otherwise. If unsure, consult your AHJ.
These wires attach to a sensor to prevent the DE MAGLOCK from force-releasing if someone from outside pulls the door open. When the sensor is in detection, the DE MAGLOCK will not start the releasing timer.
No. One sounder is required for each lock. The lock sounder that was installed in the alarm will sound.
Yes. DIP switches 5 through 8 on DIP bank 1 allow for 0 to 15 seconds lock release time.
NOTE: Local codes may dictate/mandate/require otherwise. If unsure, consult your AHJ.
Yes. DIP switch 8 on DIP bank 2 allows for red or green LED options.