Yes. BEA provides a 12/24-volt version and a 110-volt version.
Yes. The MATRIX D offers one-way detection when in “combined mode.”
This is an error indication due to the loop frequency being out of specification. Refer to the User’s Guide to determine the error.
Set DIPs 5 and/or 7 to pulse (ON). Set DIPs 6 and/or 8 to pulse on exit (ON).
[relay A = DIPs 5 and 6; relay B = DIPs 7 and 8]
No. The harness (10MATRIXHARN) is optional. Only the plug-in socket is included.
Turn on ASB (Automatic Signal Boost).
Yes. The MATRIX II is capable of controlling two loops. Use appropriate DIP switches to configure.
When setting up the loops, make sure to set the sensitivity POT to halfway, then plug the MATRIX back in. This gives you the option to adjust up and down if needed.
It can be any size, up to 108 square feet.
The number of turns will be determined by the area of the loop (see User’s Guide for the correct number of turns).
15 twists per yard.