ArtboardairporthospitalsindustrylogisticsretailfacebookinstagramlinkedintwitterwechatYouku-iconyoutubei-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Tuning

Automatic

Connector

11-pin male (86CP11)

Presence Time

1 min – infinity

Pulse Time Output

100 ms or 500 ms

LED Indicators
Green
Red

 
Power
Loop Status 1 / Loop Status 2

Frequency Range

20 kHz – 130 kHz

Frequency Steps
Single Loop
Double Loop

 
4
2 (for each loop)

Sensitivity (ΔL/L)

0.005 – 0.5%

Reaction Time
Single Loop
Double Loop

 
25 ms
50 ms (each channel)

Setup Time After Configuration

2 s max by channel

Power Supply
(depending on model)

12 – 24 AC / DC ±10%
115 VAC ±10%

Power Frequency

48 – 62 Hz

Power Consumption

< 2.5 W

Temperature Range

-22 – 158 °F (-30 – 70 °C)

Protections

Loop Insulation Transformer
Zener Diodes
Gas Discharge Clamping

Inductance Range

20 – 1000 μH

Connection

86CP11 (Standard 11-Pin Round)

Relay Outputs
Max. Contact Voltage
Max. Contact Current

2 (free potential change-over contact)
230 VAC
5 A (resistive)

Setup Time at Power On

8 s max by channel

Norm Conformity

R&TTE: 1999 / 5 / EC
EMC: 89 / 336 / EEC
EMC: 89 / 336 / EE
EMC: 2004 / 108 / EC
FCC: 47 CFR 15
IC: RSS-210 ISSUE 5
UL Listed equipment for UL 508

Degree of Protection

IP40

Weight

7 oz

Dimensions

1 ½” (W) × 3” (H) × 3” (D)