Verify that h1, h2, and d1 are all set for the given application.
Verify that the “WET/DRY” jumper is set to “WET” and the “AC/DC” jumper setting matches the power requirements of the electric strike. Also verify that the h1 timer is set to anything other than “00.”
Yes. It will still lock and disable the outside push plate. The Emergency Add-On kit may also be used.
Yes. You can use any dry-contact, secure device in place of the exterior push plate.
Verify that your door switch on IN4 and GRND is correct.
You will need to qualify which sensor will work for your size and layout of bathroom.
The BR3-X function must match the type of electric strike. I.e. Fail Safe = nU, Fail Secure = nL.
No. MOV is built in to the BR3-X.
Yes. Verify your amperage; you may need need to use an external power supply for that device.
Verify that the door position switch is closed when door is closed.
Place a jumper on IN4 of the BR3-X and test.