i-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitairporthospitalsindustrylogisticsretailArtboardempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Detection mode:

Motion
minimum detection speed: 2 in/s

Presence
typical response time: < 200 ms
(max: 500 ms)

Technology:

Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power:
< 20 dBm EIRP
Transmitter power density: < 5 mW/cm2

Active infrared with background analysis
Spot: 2” × 2” (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2

Mounting height:

6’6” – 11’6”
 
local regulations may impact acceptable mounting height (pedestrian
applications only)

Sensor temperature
range:

-13 – 131 °F *
0 – 95% relative humidity, non-condensing
 
LCD screen is operational from 14 – 131 °F.
The sensor may still be programmed in colder temperatures, but with
the remote control.

Output
Relay 1
 
 
 
 
 
Relay 2

 
Electromechanical relay (potential and polarity free)
Max. contact current: 1 A
Max. contact voltage: 30 VAC
Adjustable hold time: 0.5 – 9 s
 
Solid-state relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 VDC / 30 VAC

Test/Monitoring input:

Sensitivity:
Low: < 1 V
High: > 10 V (max. 30 V)
 
Response time on test request: typical < 5 ms

Supply voltage:

12 – 24 VAC ±10%
12 – 30 VDC ±10%
 
to be operated from SELV-compatible power supplies only

Power consumption:

< 2.5 W

Noise:

< 70 dB

Degree of protection:

IP54

FCC certification:

FCC: G9B-100606
IC: 4680A-100606

Compliance:

ISO 13849 PL «c» CAT. 2
(under the condition that the door control system monitors the sensor
at least once per door cycle)