ArtboardairporthospitalsindustrylogisticsretailfacebookinstagramlinkedintwitterwechatYouku-iconyoutubei-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Technology

LASER scanner, time-of-flight measurement, background analysis

Detection mode

Presence

Max. detection range

13’ (diagonal)
(e.g. @ 40’ width, max. height is 16’)

Number of curtains

1

Measurement points

400

Angular resolution

0.27°

Angular coverage

110°

Min. object size

¾” (depending on the settings and the installation)

Optical characteristics

IR LASER, Class 1
wavelength: 905 nm
output power: < 0.1mW

Supply voltage

12 – 24 VDC ±15%
The equipment must be powered by a SELV limited power source ensuring double insulation between primary voltages and the Equipment supply.
The supply current should be limited to 1.5A.

Power consumption

≤ 2 W

Typ. response time

400 ms

Peak current at power-on

0.8A (max. 20 ms @ 24 VDC)

Cable length

16.4’

Output
max. switching voltage
max. switching current

2 solid state relays (galvanic isolation - polarity free)
42 VAC/VDC
100 mA

Input
max. contact voltage
voltage threshold

1 optocoupler (galvanic isolated - polarity free)
30 V DC (over-voltage protected)
Log. H: >8 VDC
Log. L: <3 VDC

LED signals

1 tri-colored LED: detection/output status

Dimensions

5 3⁄5” (L) × 3 11⁄32” (H) × 1 ⅓” (D)
(mounting base adds ½”)

Material / Color

PC, ASA / black

Tilt angles

-2 – 6° (with mounting base)
2 – 10° (without mounting base)

Protection degree

IP54

Temperature range

-22 – 140 °F if powered
14 – 140 °F without power

Humidity

0 – 95% non-condensing

Vibrations

< 2 G

Compliance

IEC 60335-2-103
ISO 13849-1 (PL “d”); IEC 61508 (SIL2)

See all our products

Subscribe to our newsletter

Learn more